Description and Specification for Lab Tenders
Reciprocating Pump Test Setup.
The Set-up is designed to study the performance of Reciprocating Pump. The Set-up consists of a Reciprocating Pump coupled with electrical motor, supply tank, measuring tank & pipe fittings for closed loop water circulation. Pressure and Vacuum Gauge are connected on delivery and suction side of pump for the purpose of measurement. The flow rate of water is measured using measuring tank and stop watch provided.
EXPERIMENT:-
To determine overall efficiency and pump efficiency of the Reciprocating Pump
To plot Head vs. Discharge, Pump efficiency vs. Discharge
FEATURES:-
Closed loop water circulation
Compact & stand alone set-up
MS Excel sample calculation program on demand
Stainless Steel tanks and wetted parts
Superb painted structure
Simple to Operate & Maintain
UTILITIES REQUIRED:-
Electric Supply: - Provide 230 +/- 10 VAC, 50 Hz, Single Phase Electric Supply with proper earthing.
(Neutral - Earth voltage less than 5 VAC) 5 A, three pin socket with switch for pump.
Water Supply: Tap water connection ½" BSP., Distilled water @ 80 Ltrs. (Optional extra cost)
TECHNICALS SPECIFICATIONS: -
Pump : Double acting, single Cylinder, Capacity 1 HP Speed 250 RPM (max.), Head 5 Kg/cm2 (max.)
Drive : AC Motor with step cone pulley arrangement for 3 prefixed speed
Or DC Motor with DC Drive along with non-contact type Digital RPM
Indicator
Supply Tank : Capacity 70 Ltrs.
Measuring Tank : Capacity 50 Ltrs. fitted with Piezometer Tube & Scale
Piping : GI / PVC
Stop Watch : Electronic
Control Panel : With required electrical instrumentation
The whole Set-up is well designed and arranged in a good quality painted structure.